Filter Results By:

Products

Applications

Manufacturers

Showing results: 61 - 66 of 66 items found.

  • Fully Automatic Solar Cell

    Module Laminator-H - Synopsys, Inc.

    1. Model: BSL2236OAC-H2. Effective lamination area: 2200mm × 3600mm3. Dimensions: length 17410mm × width 3665mm × height 2164mm4. Heating method: heat conduction oil heating5. Compressed air source pressure: 0.6~0.8MPa6. Working vacuum degree: 100~40Pa7. Evacuation rate: 70L/S8. Temperature control accuracy: ±1.5°C9. Temperature control range: room temperature - 180°C10. Temperature uniformity: effective lamination area≤±2℃11. Lamination chamber height: 30mm12. Evacuation time: depending on the process, it is recommended to take 5 to 8 minutes13. Upper cover stroke: 300mm

  • Dew Point Monitor

    DPM-99 - Edgetech Instruments

    The NFPA99 has mandated that for Med Gas systems the "dew point for locally compressed air shall be monitored and alarmed per 4-3.1.9.8 and 4-3.1.1.2(f) to protect from line pressure dew point rise to 39 degrees F (3.9 degrees C) from a nominal design of 35 degrees F (1.7 degrees C)." This safeguard was the foundation for the new Edgetech Instruments DPM-99 Med Gas Dew Point Monitor. This specifically designed monitor exceeds the requirements set forth by the NFPA and was a collaboration with AIRVAC Technical Services who are certified by P.IP.E as medical gas inspectors in all 50 US States.

  • Fully Automatic Solar Cell Module

    Laminator - Three Chambers - Qinhuangdao Boostsolar Photovoltaic Equipment Co., Ltd

    1. Effective lamination area : 2400mm × 4500mm2. Dimensions: see outline drawing3. Heating method: heat conduction oil heating (63KW heating station)4. Compressed air source pressure : 0.6 ~ 0.8MPa5. Working vacuum degree: 100 ~ 40Pa6. Evacuation rate: (according to vacuum pump)7. Temperature control accuracy: ±1.5°C8. Temperature control range: room temperature - 180°C9. Temperature uniformity: effective lamination area ≤ ± 2 ℃10. Lamination cavity height: 30mm11. Evacuation time: depending on the process, it is recommended to take 5 to 8 minutes12. Upper cover stroke: 300mm13. Cooling power: 20KW

  • Dew Point Meter

    RH600 - Extech Instruments Corporation

    The Extech RH600 accurately measures and datalogs dew point levels in compressed air systems. This high-precision meter can help manufacturing professionals protect product quality while avoiding damaged pneumatic equipment, corrosion, and problems in cylinder and valve systems. Featuring a color graphical display, the RH600 provides clear, stable readings, allowing you to measure dew point temperature down to -50°C (-58°F) in max ambient pressure of 20 bar. Set high/low audible and visible alarms for temperature, relative humidity, and dew point thresholds. You can also easily log and transfer recorded data to a PC in CSV format to create inspection reports fast.

  • Torque Wrenches

    Mountz Inc.

    Versatile, accurate, and reliable, Mountz hand torque wrenches can be depended on for even the most critical fastening applications and are perfect for applications where compressed air and electric power can’t reach. Hand torque wrenches go where they’re needed, preventing bolt failures in the factory, on the road, on the rail, out at sea, and in the sky. Mountz click wrenches, break-over wrenches, and cam-over wrenches meet diverse fastening needs, while insulated torque wrenches keep electrical workers safe. Trusted in industries with stringent torque requirements and zero tolerance for failure, Mountz torque wrenches meet or exceed the accuracy and repeatability requirements of ISO 6789. With Mountz, you have the gold standard in quality and process control.

  • Dual Vapor Gravimetric Sorption Analyzer

    DVS Resolution - Surface Measurement Systems

    DVS Resolution’s key feature is the combined ability to precisely control and measure temperature and relative humidity while recording the highest resolution changes in mass. DVS Resolution uses a dry carrier gas typically nitrogen or compressed air for its operation. Digital mass flow controllers regulate flows of dry and saturated gases. Relative humidity is generated by precisely mixing dry and saturated gas flows in desired flow ratios which produce expected relative humidity. In a typical experiment a known concentration of water vapor is delivered over a sample placed inside the sample pan connected to the Surface Measurement Systems Ultrabalance™ measuring realtime mass changes caused by sorption or desorption of water molecules. Prior to sorption measurements, the sample can be in-situ preheated/dried at temperatures of up to 300oC.

Get Help